A unique case of foreign body aspiration and recurrent pneumothorax

Submitted: 7 September 2017
Accepted: 15 November 2017
Published: 15 December 2017
Abstract Views: 1303
PDF: 765
HTML: 133
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Paediatric foreign body aspiration can be related to a high morbidity/mortality rate, especially in young children, and pneumothorax can be a severe associated issue. We describe a case of a 13-year-old girl with recurrent pneumothorax in bilateral bullous lung, twice previously treated at our institution by robotassisted bullectomy, and once again showing same signs and symptoms. At conventional thoracoscopy an inorganic foreign body was found to be located pointing upwards the apex. We believe this may have acted as a contributory cause in the persistence of the clinical picture, despite the surgical removal of the underlying pathology.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

How to Cite

Lima, M., Ugolini, S., Di Salvo, N., Libri, M., Gargano, T., & Ruggeri, G. (2017). A unique case of foreign body aspiration and recurrent pneumothorax. La Pediatria Medica E Chirurgica, 39(4). https://doi.org/10.4081/pmc.2017.171